Itho Daalderop Heat Pump Error Code A1 16
Code 16 is a message, not a fault: someone has set an automatic function or setting to manual operation, for example during maintenance. The unit keeps working, but the automatic control for that part stays off until an installer switches it back with the service tool.
Also shown as: A01 16
Applies to: Itho Daalderop WPU 5G and older WPU types with an MFT thermostat (shown there as A01)
Common causes
- During service or maintenance an automatic function was set to manual operation and not switched back
- A setting was changed via the service tool, leaving the unit in manual operation
What to check, in order
- This is not a defect: the heat pump usually keeps heating as normal, but an automatic function is switched off.
- Check whether the home reaches temperature as normal and there is enough hot water.
- Have your installer or service organisation switch manual operation off again with the Itho Daalderop service tool, so everything works automatically again.
Clear the code and test
- Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back.
- Make sure the heat pump has power and the controller is set to heating or hot water, as you need it.
- Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
- If the unit runs a full cycle with no code, the fault is cleared. If the code returns, write down the code and what the unit was doing (heating, hot water or defrosting) before calling a technician — it speeds up the diagnosis.
When to call a professional
This display is not a fault, so there is normally nothing to book. Call a technician only if the machine also behaves abnormally, or if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code A1 16, your model number (on a label on the type plate, usually on the side of the unit) and the checks you already ran. It shortens the visit.
Questions people ask about A1 16
What does A1 16 mean on a Itho Daalderop heat pump?
A1 16 means: An automatic function or setting has been switched to manual operation. Code 16 is a message, not a fault: someone has set an automatic function or setting to manual operation, for example during maintenance. The unit keeps working, but the automatic control for that part stays off until an installer switches it back with the service tool.
Can I fix Itho Daalderop A1 16 myself?
There is nothing to fix: code A1 16 is a status display, not a fault. The checks on this page show how to exit the mode or confirm the setting.
How do I clear Itho Daalderop A1 16?
Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back. Make sure the heat pump has power and the controller is set to heating or hot water, as you need it. Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
Sources checked
- Itho Daalderop WPU 5G user manual (manufacturer document)
- Itho Daalderop service chapter: WPU 5G faults (JK Engineered Solutions)
The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.